AISIKAI MCCB Normal working conditions and installation methods |
|
Category | Requirements |
Elevation | Installation site not exceeding 2000 meters above sea level |
Ambient air temperature | The upper limit does not exceed+ 40 ºC; the lower limit does not exceed - 5 ºC; the average value of 24 hours does not exceed + 35 ºC |
Pollution Level | Level 3 |
Installation Category | Installation Category III, Circuit Breaker 1600A IV |
Atmospheric conditions |
Atmospheric relative humidity does not exceed 50% when the ambient air temperature is + 40 C. It can have a higher relative humidity at a lower temperature. The average maximum relative humidity of the wettest month is 90%, and the average minimum temperature of the month is + 25 C. Considering the condensation occurring on the surface of the product due to temperature changes. |
Installation Conditions |
Installed in places without significant shaking and shock vibration, the magnetic field near the installation site should not exceed 5 limes of the magnetic field in any direction, and leakage circuit breakers should generally be installed vertically. |
Installation | Circuit breaker can be installed vertically (i.e. vertically) or horizontally (i.e. horizontally). |
Input mode | Circuit breaker can't go down, that is, only 1,3,5 power lines, 2,4,6 load lines |
Model | ASKM1E-125 | ASKM1E-250 | |||||||
Frame rating current Inm(A) | 125 | 250 | |||||||
Rated current In(A) | 32 | 63 | 125 | 160 | 250 | ||||
Overload long delay setting cument Ir(A) |
12.5,16, 20,25,32 |
32,36,40, 45,50,55, 60,63 |
63,65,70, 75,80,85,90, 95,100,125 |
63,80,90,100,125, 140,160 |
100,125,140,160, 180,200,225,250 |
||||
Rated operational voltage Ue(V) | AC400V/415V AC660V/690V | ||||||||
Rated insulation voltage Ui(V) | 1000V | ||||||||
Rated impulse withstand voltage Uimp(V | 12000V | ||||||||
Arc distance(mm) | ≯50(0)2) | ≯50(0)2) | |||||||
Breaking capacity leve | M | H | M | H | |||||
UItimate short-circuit breaking capacity lcu(kA |
AC400V/415V | 50 | 85 | 50 | 85 | ||||
AC660V/690V | 20 | 20 | 20 | 20 | |||||
Service short-circuit breaking capacity Ics(kA) |
AC400V/415V | 35 | 50 | 35 | 50 | ||||
AC660V/690V | 15 | 15 | 15 | 15 | |||||
Rated short-time withstand cument Icw(kA/1s | 5 | 5 | |||||||
Use category | B | B | |||||||
Electnical service ife(times) |
8000 | 8000 | |||||||
Mechanical service ife(times) |
without maintenance | 20000 | 20000 | ||||||
with maintenance | 40000 | 40000 | |||||||
Outline dimensions (mm) |
W(3P/4P) | 92/122 | 107/142 | ||||||
L | 150 | 165 | |||||||
H(not including handle) | 92 | 90 |