MAIN TECHNICAL PARAMETERS | |||||||||||||
SKT2 Series | SKT1 Series | ||||||||||||
Frame rating current (Inm) | 100A | 160A | 250A | 630A | 1600A | 3200A | |||||||
Rated current (In) | 100 | 125A | 160 | 250 | 400 | 630 | 800 1000 | 1250 1600 | 2000 | 2500 | 3200 | ||
Thermal current rating (lth) | 10,16,20,25 32,40,50,63 80,100A |
63,80,100 125,140 150,160A |
125,140,160,180 200,225,250A |
160,180,200 225,250,315 350.400.500 630A |
800,1000,1250, 1600A |
2000,2500,3200A | |||||||
Rated insulation voltage of copper bar (Ui) | 1000V | ||||||||||||
Rated impulse withstand voltage (Uimp) | 12KV | ||||||||||||
Rated operational voltage of copper bar (Ue) | AC400V | ||||||||||||
Use category | AC-33A | ||||||||||||
Rated operational current of copper bar (le) | 10,16,20,25,32,40,50,63,80,100,125,140,150,160,180,200,225,250,315,350,400,500,630 | 800,1000,1250,1600,2000,2500,3200 | |||||||||||
Rated making capacity | 10le | ||||||||||||
Rated breaking capacity | 10le | ||||||||||||
Rated limit short- circuit current (lq) |
fuse for protection | 100KA | 100KA | 100KA | 120KA | 120KA | 120KA | ||||||
circuit breaker for protector | 50KA | 50KA | 50KA | 65KA | 65KA | 65KA | |||||||
Transferring time 1-2 or 2-1 | 1.2S | 0.6S 1.2S 2.4S | |||||||||||
Rated operational voltage of the control power supply | AC220V (special voltage DC24V,DC110V,DC220V,AC110V,AC280V) | ||||||||||||
Start | 40W | 325W | 355W | 400W | 440W | 600W | |||||||
Normal | 18W | 62W | 74W | 90W | 98W | 120W | |||||||
Net weight(kg)4 poles | 3.5 | 5.3 | 5.5 | 7 | 17 | 17.5 | 37 | 44 | 98 | ||||
Note:The parameters of SKT120A-100A are exactly same as the SKT1125A product |
NORMAL OPERATIONAL CONDITIONS AND INSTALLATION METHODS | |
Category | Requirement |
Operational temperature | Between -20ºC and 45ºC.The average value in 24 hours does not exceed +35ºC |
Operational humidity | The average humidity at +40ºC shall not exceed 50%without condensation |
Altitude | Lower than 2000 meters.Operation at altitude above 2000 meters requires derating |
Vibration and gas | Use environment should be without strong vibration and shock,and without harmful gases that corrode metals and destroy insulation |
Ambient substance | Without heavy dust,conductive particles and explosive hazardous substances |
Pollution level | 3 |
IP rating | IP 20 |
Storage requirements | Storage environment should be between -30ºC and 70ºC,dry,non-corrosive and non-saline.The maximum storage time is 1 year |
Packaging | Carton packaging for 630A and below;wooden crate packaging for 800A and above |
Stacking | No more than 5 layers for 630A and below;no more than 3 layers for 800A and above |
Installation method | Install vertically or horizontally.Upside down installation is prohibited |
Wiring method | Standard is top inlet and bottom outlet.Bottom inlet and top outlet can be customized |
AISIKAI Automatic Transfer Switch Fast Reading Diagram For Cabinet Body Installation | |||||||
Current(A) | Switch Lmax(mm) | Switch Wmax(mm) | Switch Hmax(mm) | Recommended cabinet L*W*H(mm) |
Compact cabinet L*W*H(mm) | ||
10~100 | 290 | 195 | 142 | 500 X 400 X 800 | 500 X 250 X 600 | ||
125-160 | 290 | 195 | 142 | ||||
250 | 359 | 195 | 170 | ||||
400-630 | 433 | 262 | 270 | 600 X 500 X 1800 | 550 X 450 X 1600 | ||
800-1250 | 633 | 321 | 350 | 800 X 600 X 2000 | 720 X 600 X 1800 | ||
1600 | 633 | 321 | 407 | 800 X 600 X 2200 | 720 X 600 X 2000 | ||
2000-3200 | 633 | 500 | 470 | 800 X 800 X 2200 | 720 X 800 X 2000 | ||
1. Switch maximum length(Lmax) is the distance from the left elevation of the left installation bracket to the right installation bracket. 2. Switch maximum width0Nmax) is the distance from the rear elevation of the installation bracket to the front elevation of the manual emergency handale interface. 3. Switch maxmum height{Hmax) is the distance from the top elevation of the upper copper bar to the bottom elevation of the bottom copper bar. 4. Forthe cabinet height,please consider the actual situation of the space required for the operation and connection of the cables. |
|||||||