Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Electric Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
AISIKAI MCCB Normal working conditions and installation methods |
|
Category | Requirements |
Elevation | Installation site not exceeding 2000 meters above sea level |
Ambient air temperature | The upper limit does not exceed+ 40 ºC; the lower limit does not exceed - 5 ºC; the average value of 24 hours does not exceed + 35 ºC |
Pollution Level | Level 3 |
Installation Category | Installation Category Ill, Circuit Breaker 1600A IV |
Atmospheric conditions |
Atmospheric relative humidity does not exceed 50% when the ambient air temperature is + 40 C. It can have a higher relative humidity at a lower temperature. The average maximum relative humidity of the wettest month is 90%, and the average minimum temperature of the month is + 25 C. Considering the condensation occurring on the surface of the product due to temperature changes. |
Installation Conditions |
Installed in places without significant shaking and shock vibration, the magnetic field near the installation site should not exceed 5 limes of the magnetic field in any direction, and leakage circuit breakers should generally be installed vertically. |
Installation | Circuit breaker can be installed vertically (i.e. vertically) or horizontally (i.e. horizontally). |
Input mode | Circuit breaker can't go down, that is, only 1,3,5 power lines, 2,4,6 load lines |
Model | ASKM1-63 | ASKM1-125 | ASKM1-250 | ASKM1-400 | ||||||||||
Frame rating current Inm(A) | 63 | 160 | 250 | 400 | ||||||||||
No.of poles | 3P/4P | 3P/4P | 3P/4P | 3P/4P | ||||||||||
Rated current In(A) | 10,16,20,25, 32,40,50,63 |
10,16,20,25,32, 40,50,63,80,100, 125,140,160 |
100,125,140,160, 180,200,225,250 |
225,250,315, 350,400 |
||||||||||
Rated insulation voltage Ui(V) | 1000V | 1000V | 1000V | 1000V | ||||||||||
Rated impulse withstand voltage Uimp(V | 12000V | 12000V | 12000V | 12000V | ||||||||||
Rated operational voltage Ue(V) | AC400V/415V AC660V/690V | |||||||||||||
Arc distance(mm) | ≯50(0)2) | ≯50(0)2) | ≯50(0)2) | ≯100(0)2) | ||||||||||
Breaking capacity level | L | M | H | L | M | H | L | M | H | L | M | H | ||
Ultimate short-circuit breaking capacity lcu(kA) |
AC400V | 25 | 35 | 50 | 35 | 50 | 65 | 35 | 50 | 65 | 65 | 70 | 100 | |
15 | 20 | 20 | ||||||||||||
Service short-circuit breaking capacity Ics(kA) |
AC400V | 18 | 22 | 35 | 22 | 35 | 50 | 25 | 35 | 50 | 65 | 70 | 100 | |
15 | 20 | 20 | ||||||||||||
Use category | A | A | A | A | ||||||||||
Electrical service ife(times) |
AC400V/415V | 8000 | 8000 | 8000 | 7500 | |||||||||
AC660V/690V | 1500 | 1500 | 1000 | 1000 | ||||||||||
Mechanical service ife(times) |
without maintenance | 20000 | 20000 | 20000 | 10000 | |||||||||
with maintenance | 40000 | 40000 | 40000 | 20000 | ||||||||||
Outline dimensions (mm) |
W(3P/4P) | 75/100 | 92/122 | 107/122 | 150/198 | |||||||||
L | 130 | 150 | 165 | 257 | ||||||||||
H(not induding handle) | 60 | 92 | 90 | 106.5 |