• Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE
  • Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE
  • Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE
  • Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE
  • Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE
  • Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE

Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE

Output Type: DC
Cooling
Method:
Air Cooled
Installation
Method:
Fixed
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE pictures & photos
Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE
US $20-25 / Piece
Min. Order: 1 Piece
Diamond Member Since 2013

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
BAC06A
Generator
Type
Diesel Generator
Model
Bac1206
Max Output Power
135W
Dimension
143*96*55mm
Stock
2000PCS
Transport Package
by Express/Sea
Specification
12V/24V
Trademark
AISIKAI
Origin
Yangzhou
HS Code
8409999990
Production Capacity
200PCS/Day

Packaging & Delivery

Package Size
35.00cm * 14.00cm * 21.00cm
Package Gross Weight
25.000kg

Product Description

Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE

BAC series switch b5attery chargers use the latest switch power .
devices. Designed according to the charge characteristics of the .
lead-acid battery for starting generators, BAC chargers are suitable for the long time
supplement charge(floating charge) of the lead-acid battery. The maximum charging
current is 6A for 12V and 10A for 24V.


 
Category Items 12V 24V
Model BAC BAC-1206 BAC-2403/2405/2410

Input
Nominal input voltage AC(100~240)V
Max input voltage AC(90~305)V
Frequency 50Hz/60Hz
Max input current 2.5A 2.5A/2.5A/4A
Efficiency >85%

Output
Charging current 4A~6A,error±2% 2A~3A/5A/10A,error±2%
Factory charging current 6A 3A/5A/10A
Max output power 135W 135W/135W/290W
Min output voltage 7.5V
No-load output voltage 13.8V,error 1% 27.6V,error 1%
No-load consumption <3W

Insulation
Insulation resistance When between input and output, output and shell are
both DC500V 1min, the insulation resistance RL≥50MΩ
Insulation voltage When between input and output, output and shell are both AC1500V 50Hz 1min, the leakage current IL≤3.5mA
Working conditions Working temperature (-30~55)ºC
Storage temperature (-40~85)ºC
Working humidity 10%RH~95%RH(no condensation)

Structure
Weight 0.65kg 0.65/0.65/1.15kg
Dimensions(L*W*H mm) 143*96*55(3A/5A/6A); 205*146*55(10A);


PERFORMANCE FEATURES

1. Designed in switch power structure. Wide range of the input voltage. Small volume,
light weight and high efficiency.
2. Automatic charge using the 2-stage charging method(i.e., constant current first and
then constant voltage). The process
is in full accordance with the battery charging characteristics, and can prevent
overcharging of lead-acid battery and maximize battery life.
3. Have protection functions for short-circuit and reverse connection.
4. Charging voltage and current can be regulated by potentiometer on site.
5. LED status display: AC power indication, charging indication
6. Horizontal instllation. Easy to install.

Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE

CONFIGURATION

Voltage regulation

When regulating voltage on site, it is needed to disconnect the battery from the charger.
Measure the charger output voltage while regulating the voltage potentiometer (VOLT)
until the appropriate value is reached.

Current regulation
Connect the output to the battery. Measure the charging current when the charging
voltage is not higher than 25.0V (12.5V). Regulate the current potentiometer (AMP) to
set the appropriate charging current.
The output current can also be estimated according to the current potentiometer scale.

Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE
Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE
Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE

Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE
Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE
Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE pictures & photos
Aisikai Constant Voltage Power Supply DC12/24V ATS Generator Battery Charger CCC/CE
US $20-25 / Piece
Min. Order: 1 Piece
Diamond Member Since 2013

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
Year of Establishment
2007-02-07
Management System Certification